Rated Current Fusible Resistor (RFA Series)


FEATURES :
The rated current fusible combines time delay performance Characteristics
    with the proven reliability of a rated current fusible.


CHARACTERISTICS:
ITEM
REMARKS

Load life under high temperature

JIS C 5201-1(4.25.1)    Rated current at 50%;70℃ for 1,000 hours

Humidity resistance

JIS C 5201-1(4.24)    MIL-STD-202,Method 106,Heat(65℃ at 90%∼98%).

Vibration

JIS C 5201-1(4.22)    MIL-STD-202,Method 213,Condition 1.

Thermal shock

JIS C 5201-1(4.19)    MIL-STD-202,Method 107, Test Condition B.(-25℃∼85℃)

Insulation resistance

JIS C 5201-1(4.6.1.1)   MIL-STD-202,Method 302(≧10KΩ at 500V)

Resistance to soldering heat

JIS C 5201-1(4.18)    MIL-STD-202,Method 210,Test Condition C.(10s at 260℃)

Solderability

JIS C 5201-1(4.17)    MIL-STD-202,Method 208. .(5s at 245℃).>95%

Lead pull force

JIS C 5201-1(4.16)    MIL-STD-202,Method 211, Test Condition A.

Salt Mist Spray

MIL-STD-202     Method 101,Condition B.

 

ORDERING INFORMATION

CURVE OF TEMPERATURE AND RATED CURRENT

FUSE CURVE OF RATED CURRENT

Order
Number

Amperes
Rating

Voltang
Rating

Cold
Olrm

Body Size

Melting
I2t(A2*s)

A100

1/10

125

100

25*65

0.02

A250

1/4

125

15.0

25*65

0.125

A375

3/8

125

6.80

25*65

0.28

A500

1/2

125

3.60

25*65

0.50

A750

3/4

125

1.6

25*65

1.12

1A00

1.00

125

0.9

25*65

2.00

1A50

1.1/2

125

0.39

25*65

5.50

2A00

2.00

125

0.23

25*65

8.00

2A25

2.1/4

125

0.25

25*65

10.12

2A50

2.1/2

125

0.20

25*65

12.5

3A00

3.00

125

0.13

25*65

18.0

4A00

4.00

125

0.12

28*92

32.0

5A00

5.00

125

0.15

28*92

50.0

7A00

7.00

125

0.10

28*92

98.0

 

Model

Dielectric
Withstanding
Voltage

Dimension (mm)

L

ι

A100,A250,A375,A500,A750,1A00,1A50

100V

6± 0.3

2.4± 0.1

28± 2

0.60± 0.05

Various types of forming & taping are available.

Coating color:RFU (gray)

2A00,2A25,2A50A,3A00

4A00,5A00,7A00

100V

9± 0.5

3.0± 0.5

30± 3

0.60± 0.05

 

FUSE CHARACTERISTICS:

Percentage of Ampere Rating

Opening Time

100%

4Hour Minimum

200%

1 second~ 60 seconds Max

300%

0.2 second ~ 3seconds Max

800%

0.02 second ~ 0.2seconds Max

INTERRUPTING RATING

50 Ampere At 125V DC;50 Ampere At 125V AC

OPERATING TEMPERATURE

-55℃∼130℃

 

...............................................................................................................................................................................................................................................